Boiler efficiency, blowdown and heat recovery

Estimate boiler efficiency from losses, using fuel, O₂ and stack temperature, find the minimum blowdown from TDS and see what combustion tuning, an economizer and blowdown heat recovery are worth.

Pre-sizing and estimating tool: results do not replace design, calculations or reports signed by a licensed professional, nor verification against the applicable codes and standards.

Preliminary estimate
Boiler
Combustion
Blowdown

With automatic blowdown control, the rate drops to the minimum the TDS requires.

Economic analysis
—Estimated boiler efficiency today
—

Energy losses, today and with improvements

Share of fuel energy (LHV) lost in each item.

Tap the chart to see the values.

Efficiency versus flue gas O₂

LHV-basis efficiency at today’s stack temperature and with an economizer.

Tap the chart to see the values.

Next step

Take this page’s results to another calculator with the fields already filled in.

Project payback

Cash flow of the improvement: investment in year 0 and annual savings escalated at the rate entered, discounted at the MARR.

Tap the chart to see the values.

The report gathers this page's inputs, results, equations, assumptions and references, with fields for project, engineer and revision. In the print dialog, choose Save as PDF.

Method, assumptions and references

Equations used

Stoichiometric O₂: O₂st = 2.664·C + 7.937·H + 0.998·S − O [kg/kg]; theoretical air A0 = O₂st ÷ 0.2314
Excess air from dry O₂: EA = O₂ ÷ (20.9 − O₂)
Dry flue gas: mdg = 3.664·C + 1.998·S + 0.7686·A + N + 0.2314·A0·EA; loss = mdg · 1.04 · (Tg − Ta) ÷ LHV
Flue gas moisture: mw = 8.936·H + M; loss = mw · 1.88 · (Tg − Ta) ÷ LHV
Efficiency (LHV) = 1 − losses; efficiency (HHV) = efficiency (LHV) × LHV ÷ HHV
Minimum blowdown (% of steam) = TDSfeed ÷ (TDSmax − TDSfeed); energy = ṁbd × (hf(p) − h(Tmake-up))
Blowdown flash: x = (hf(p) − hf(pf)) ÷ hfg(pf); exchanger: ṁbd (1 − x) (hf(pf) − h(Tout))

Assumptions and limits

  • Complete combustion (no CO); mean specific heats of 1.04 kJ/(kg·K) for dry gas and 1.88 kJ/(kg·K) for water vapor; air humidity neglected.
  • Typical fuel compositions on a dry basis; for test-grade results, use your fuel’s ultimate analysis and the full ASME PTC 4 procedure.
  • Efficiency on an LHV basis (Brazilian and European practice); the HHV equivalent (U.S. practice) is also shown.
  • Radiation, ash and unburned losses enter as one percentage entered by the user.

Standards and technical documents

  • ASME PTC 4-2013: Fired Steam Generators (indirect efficiency, energy balance method)
  • EN 12952-15:2003: Water-tube boilers and auxiliary installations — Acceptance tests
  • ASME (1994/2021): Consensus Operating Practices for Control of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers
  • U.S. DOE, Steam Tip Sheets #4 (Improve Your Boiler’s Combustion Efficiency), #9 (Minimize Boiler Blowdown) and #10 (Recover Heat from Boiler Blowdown)
  • IAPWS R7-97(2012): water and steam properties

U.S. regulations

  • EPA 40 CFR Part 63, Subpart DDDDD (major sources) and Subpart JJJJJJ (area sources): periodic boiler tune-ups with O₂ and CO measurement and one-time energy assessments
  • ASME BPVC Section I and Section VI/VII guidance, enforced through state boiler and pressure vessel laws (National Board NBIC)
  • EPA 40 CFR 403.5(b)(5): blowdown discharged to a POTW must not raise influent above 40 °C (104 °F)

Frequently asked questions

How can I estimate boiler efficiency without metering fuel?

Use the heat-loss method: from stack O₂ and temperature and the fuel composition, compute dry gas and moisture losses; adding radiation and other losses, efficiency is 100% minus the total (ASME PTC 4).

What excess air is right?

It depends on fuel and burner. Natural gas usually runs at 2% to 3% O₂; oil 3% to 4%; grate-fired biomass 5% to 8%. Reduce it with a flue gas analyzer while watching CO.

How much energy goes out with blowdown?

Each lb of blowdown carries saturated water at boiler pressure. At 150 psig with 77 °F make-up, about 290 Btu/lb. At 8% blowdown on a 20,000 lb/h boiler, that is over 460,000 Btu/h lost continuously.