Enter the building dimensions, fixture height and activity. The page works out how many fixtures you need, how to lay them out, the power density and how much replacing the current installation saves each year.
Pre-sizing and estimating tool: results do not replace design, calculations or reports signed by a licensed professional, nor verification against the applicable codes and standards.
Luminaires in rows and columns with even spacing and half spacing next to the walls.
Same luminaire and reflectances: mounting higher lowers room index K and the utilization factor.
Cash flow of the improvement: investment in year 0 and annual savings escalated at the rate entered, discounted at the MARR.
The report gathers this page's inputs, results, equations, assumptions and references, with fields for project, engineer and revision. In the print dialog, choose Save as PDF.
For 28 fc (300 lx, machining), 20,000 lm LED high-bays at 26 ft, a 0.72 utilization factor and 0.8 maintenance factor: about 21 fixtures, in a 7 × 3 grid.
ISO/CIE 8995-1 calls for 100 lx (9 fc) in circulation and storage, 300 lx (28 fc) for welding and ordinary machining, 500 lx (46 fc) for precision machining and offices and 750 lx (70 fc) for tool making. Check ANSI/IES RP-7 for U.S. practice.
In the example, 24 metal halide fixtures of 400 W (458 W with ballast) become 21 of 150 W: power drops from 11 kW to 3.15 kW and, at 6,000 h a year and US$ 0.12 per kWh, the bill falls by about US$ 5,600 a year.
Installed power divided by floor area. A well designed LED plant lands near 0.2 to 0.45 W/ft² for 28 fc; ASHRAE/IES 90.1 sets the code maximum by space type.
Important notice: Indus Metrics tools produce estimates and pre-sizing results from the data you enter and from published engineering methods. They do not replace design, calculations or reports signed by a licensed professional engineer (PE), nor verification against the applicable codes, standards and regulations, such as OSHA rules and the ASME codes. Material and fuel properties vary: check manufacturer data or your own process analyses before deciding. By using this site you agree to the Terms of Use.