Home / Formulation & filling

Tank agitation and mixing: power, Reynolds and scale-up

Enter the tank, impeller, speed and fluid to see the flow regime, how much power the agitator draws, what motor it needs, how intense the agitation is and how to scale up to a larger tank.

Pre-sizing and estimating tool: results do not replace design, calculations or reports signed by a licensed professional, nor verification against the applicable codes and standards.

Pre-sizingRevised 11/02/2026
Tank
Impeller
Fluid
Drive
Scale-up

Changing the impeller loads typical KL, KT, diameter and speed; adjust them to your equipment. Single impeller; tall tanks (height over 1.3 times diameter) usually need two.

Your inputs stay only on this browser and are not sent anywhere. Untick to delete them.

—Power drawn by the liquid
—

Impeller power curve

Power number versus Reynolds number (log scales). The dot is the current condition.

Tap the chart to see the values.

Agitation intensity (P/V)

Usual ranges by duty (Walas) and the current tank value (line).

Tap the chart to see the values.

Scale-up by criterion

Geometrically similar larger tank. The highlighted row is the criterion chosen.

Next step

Take this page’s results to another calculator with the fields already filled in.

The calculation report gathers this page's inputs, results, equations, assumptions and references, with fields for project, engineer and revision. The full report also includes the charts and interpretations, in color. In the print dialog, choose Save as PDF.

Method, assumptions and references

Equations used

Re = ρ · N · D² ÷ μ (N in revolutions per second)
Np = KL ÷ Re (Re ≤ 10); Np = KT (Re ≥ 10⁴, baffled); in the transition, log-log interpolation between (10; KL/10) and (10⁴; KT)
P = Np · ρ · N³ · D⁵; P_motor = P ÷ η_gearbox; P/V with V = π·T²·H/4; tip speed = π · D · N
Blend time (Grenville and Nienow, turbulent, H = T): N · θ95 = 5.20 · Np^(−1/3) · (T/D)²
Scale-up: R = (V₂/V₁)^(1/3), D₂ = R·D₁; constant P/V N₂ = N₁·R^(−2/3); tip speed N₂ = N₁/R; Reynolds N₂ = N₁/R²; same speed N₂ = N₁

Assumptions and limits

  • Newtonian fluid, single centered impeller, flat or slightly dished bottom, tank with 4 baffles 1/10 of diameter wide (the KL and KT values in McCabe, Smith and Harriott Table 9.2 were measured that way). Without baffles, in turbulent flow, actual power is lower and the result is an upper bound.
  • In the transition (10 < Re < 10,000) the power number is an approximate interpolation; real curves (such as the Rushton turbine’s) have their own shapes. Non-Newtonian fluids, sparged gas and suspended solids change power and are not included.
  • Blend time applies only in turbulent flow, with baffles and liquid height close to diameter. P/V ranges are indicative (Walas). The suggested motor is the next standard rating above the power with margin; check starting and duty in the motor calculator.

Standards and technical documents

  • Paul, E. L.; Atiemo-Obeng, V. A.; Kresta, S. M. (eds.). Handbook of Industrial Mixing: Science and Practice. Wiley-Interscience, 2004 (ch. 6 mechanically stirred vessels; ch. 9 Grenville and Nienow, blending of miscible liquids)
  • McCabe, W. L.; Smith, J. C.; Harriott, P. Unit Operations of Chemical Engineering, 7th ed. McGraw-Hill, 2005, ch. 9, Table 9.2 (KL and KT)
  • Couper, J. R.; Penney, W. R.; Fair, J. R.; Walas, S. M. Chemical Process Equipment: Selection and Design, 3rd ed. Elsevier, 2012 (rules of thumb: mixing and agitation)
  • Rushton, J. H.; Costich, E. W.; Everett, H. J. Power characteristics of mixing impellers. Chemical Engineering Progress, 46, 1950, p. 395–404 and 467–476

U.S. regulations

  • OSHA 29 CFR 1910.212: General requirements for all machines (guarding)
  • OSHA 29 CFR 1910.147 (lockout/tagout) and 1910.146 (permit-required confined spaces) for tank entry

Frequently asked questions

What does this calculator do?

It works out how much power an agitator draws, its flow regime (laminar, transitional or turbulent), the motor it needs, how intense the agitation is in hp/1,000 gal, the blade tip speed, the blend time and how to scale up to a larger tank. Use it to check an existing agitator, pick speed and diameter for a new one or move a pilot recipe to production.

How is agitator power calculated?

With P = Np · ρ · N³ · D⁵, using the impeller power number Np. First the Reynolds number, Re = ρ·N·D²/μ: in the example, a 21 in pitched-blade turbine at 150 rpm in water gives Re = 710,970, turbulent flow, where Np = 1.27 is constant. Power drawn is 1.15 hp in a 5.25 ft diameter tank with 5.25 ft of liquid (850 gal).

Where do the power numbers come from?

From McCabe, Smith and Harriott Table 9.2, for a tank with 4 baffles: Rushton turbine KT 5.75 and KL 65; 4-blade 45° pitched blade KT 1.27; marine propeller KT 0.32; HE-3 type hydrofoil KT 0.28; anchor KL 300. In laminar flow Np = KL ÷ Re; in the transition the calculator interpolates, which may be off by 30% or more. As a check, the book’s Example 9.1 (2 ft disk turbine at 90 rpm in 50% caustic) gives about 2.5 kW (3.3 hp), and the calculator 2.46 kW.

What motor should I use?

Divide power drawn by gearbox and bearing efficiency and add a margin. In the example, 1.15 hp ÷ 0.95 = 1.21 hp at the motor shaft; with 15% margin, 1.39 hp, so a standard 1.5 hp motor. If the product thickens or takes on solids during the batch, size for the worst point and check starting in the motor calculator.

Is the example hp/1,000 gal value good?

The tank gets 1.35 hp/1,000 gal, in the homogeneous reaction range (0.5 to 1.5 hp/1,000 gal) from Walas’ rules of thumb. Blending needs 0.2 to 0.5; reaction with heat transfer, 1.5 to 5; gas–liquid, 5 to 10; slurries, about 10 hp/1,000 gal. These ranges are indicative: solids suspension and gas dispersion depend on the particles and gas rate, and a pilot test is worth more.

How do I scale up to a larger tank?

With geometric similarity every dimension grows by R = (V₂/V₁)^(1/3). For 6,500 gal, R = 1.97: the impeller becomes 41 in. Holding P/V, speed drops to 95 rpm and power rises to 8.78 hp; keeping the same speed would take about 34 hp. Constant P/V is the starting point for reaction, heat transfer and suspension; constant tip speed for shear-sensitive products.

What are the limits and safety precautions?

It applies to Newtonian fluids, one centered impeller and a baffled tank; without baffles a vortex forms and actual power is lower. Blend time (17 s in the example, by the Grenville and Nienow correlation) only applies in turbulent flow with liquid height close to diameter. An agitator is rotating machinery: follow OSHA 1910.212 guarding and lockout/tagout, and treat tank entry as a permit-required confined space.